BNRRV - REFRIGERANT 12
- MSDS: BNRRV
- Manufacturer: RACON INCORPORATED
- Product Name: REFRIGERANT 12
- National Stock Number: 6830-00-975-1992
Product Identification
Product ID:REFRIGERANT 12
MSDS Date:04/07/1989
FSC:6830
NIIN:00-975-1992
MSDS Number: BNRRV
Responsible Party
WICHITA, KS 67201
US
Emergency Phone: 415-821-5338
Info Phone: 800-835-2916/316-524-3245
Cage: KO001
Contractor
Telephone: 800-221-0603
Cage: 3A676
Ingredients
DICHLORODIFLUOROMETHANE (SARA III)
CAS: 75-71-8
RTECS: PA8200000
Fraction By Weight: 100%
ACGIH TLV: 1000 PPM;VOL 8HR TWA
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
LD50 LC50 Mixture:620,000PPM/3HR/MICE-800,000PPM/RAT/30MIN
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: CARDIOVASCULAR &
RESPIRATORY SYSTEMS MAY BE AFFECTED. GENERALIZED TINGLING
SENSATION, HUMMING IN EARS, APPREHENSION, SLURRED SPEECH, DECREASE
IN CONSCIOUSNESS W/AMNESIA, IRREG HEART BEAT . EYE IRRIT, CENTRL
NERV SYSTEM EFFECTS. SKIN: IRRIT. INGEST: FREEZING & FROSTBITE OF
TISSUE.*
Effects of Overexposure:* CHRONIC: INHALATION: VAPOR CAN BE FATAL.
CENTRAL NERVOUS SYSTEM DEPRESSION, SEDATION, LOSS OF COORDINATION,
MILD DEPRESSION. INGESTION: SLIGHT EFFECT ON LIVER.
Medical Cond Aggravated by Exposure:IN BRONCHITIC AND ASTHMATICS,
ARRTHYTMIAS OCCURED MOST FREQUENTLY AFTER SALBUTAMOL. HEART &
RESPIRATORY DISORDERS MAY PROVE SUSCEPTABLE TO ASPHYXIATION &
CARDIAC ARRHYTHMIAS.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. KEEP WARM & AT REST. IF
LABORED BREATHING, GIVE OXYGEN. IF NOT BREATHING, START ARTIFICIAL
RESPIRATION. IF NO PULSE, START CPR. DON'T GIVE STIMULANTS. GET
MEDICAL AID. KEEP AT REST FOR 24 HRS. EYES/SKIN: FLUSH WITH WATER
OR SALINE SOLUTION 20 MIN. GET MEDICAL AID. INGESTION: KEEP PATIENT
CALM. GET MEDICAL AID. WARM SKIN SLOWLY.
Fire Fighting
Flash Point:NONE
Fire Fighting Procedures:USE SELF-CONTAINED BREATHING APPARATUS.
Accidental Release
Spill Release Procedures:KEEP UPWIND. VENTILATE ENCLOSED SPACES UNTIL
GAS IS DISPERSED. DO NOT SMOKE OR OPERATE INTERNAL COMBUSTION
ENGINES IN IMMEDIATE VICINITY. REPORT SPILL TO NATIONAL RESPONSE
CENTER, 1-800-424-8802 IF 5, 000 LBS OR MORE.
Handling
Handling and Storage Precautions:STORE & USE WITH ADEQUATE VENTILATION.
NEVER USE IN A CLOSED OR CONFINED SPACE. STORE IN COOL PLACE
(<120F).
Other Precautions:DO NOT BREATHE VAPOR. AVOID CONTACT WITH EYES, SKIN &
CLOTHING. CFC-12 IS SHIPPED AND STORED AS A LIQUIFIED, COMPRESSED
GAS UNDER PRESSURE.
Exposure Controls
Respiratory Protection:IF CONCENTRATIONS EXCEED TLV (1,000 PPM) USE AN
APPROVED RESPIRATOR. IN VERY HIGH CONCENTRATIONS, SELF-CONTAINED
BREATHING APPARATUS SHOULD BE USED.
Ventilation:LOCAL EXHAUST MAY BE NECESSARY TO REDUCE CONCENTRATIONS
BELOW TLV (1,000 PPM).
Protective Gloves:CLOTH-LINED RUBBER GLOVES.
Eye Protection:GOGGLES, FULL FACE SHIELD
Work Hygienic Practices:NOT FOR FOOD, DRUG OR COSMETIC USE.
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:-22F,-30C
Vapor Pres:79.8 PSIG
Vapor Density:2.32 **
Spec Gravity:1.31 @77F;1 ATM
Viscosity:N/K * @ 77F
Evaporation Rate & Reference:N/K ** LB/FT3 @ 77F
Solubility in Water:INSOLUBLE
Appearance and Odor:COLORLESS LIQUID AND VAPOR; ODOR VERY SLIGHT
ETHEREAL TO ODORLESS.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
ELASTOMERS, ALKALI OR ALKALINE EARTH METALS, POWDERED ALUMINUM, ZINC,
BERYLLIUM, FINELY GROUND MAGNESIUM.
Stability Condition to Avoid:AVOID CONDITIONS WHERE CFC-12 MAY CONTACT
OPEN FLAMES OR EXTREMELY HOT METAL SURFACES.
Hazardous Decomposition Products:HF, HCL, AND TRACES OF CARBONYL HALIDE
(I.E. PHOSGENE).
Disposal
Waste Disposal Methods:THE EPA HAZARDOUS WASTE NUMBER IS U075.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.